Search results for "Single photon"
showing 10 items of 27 documents
Evaluation of Mucociliary Clearance by Three Dimension Micro-CT-SPECT in Guinea Pig: Role of Bitter Taste Agonists
2016
Different image techniques have been used to analyze mucociliary clearance (MCC) in humans, but current small animal MCC analysis using in vivo imaging has not been well defined. Bitter taste receptor (T2R) agonists increase ciliary beat frequency (CBF) and cause bronchodilation but their effects in vivo are not well understood. This work analyzes in vivo nasal and bronchial MCC in guinea pig animals using three dimension (3D) microCT-SPECT images and evaluates the effect of T2R agonists. Intranasal macroaggreggates of albumin-Technetium 99 metastable (MAA-Tc99m) and lung nebulized Tc99m albumin nanocolloids were used to analyze the effect of T2R agonists on nasal and bronchial MCC respecti…
Drug Distribution to Retinal Pigment Epithelium: Studies on Melanin Binding, Cellular Kinetics, and Single Photon Emission Computed Tomography/Comput…
2016
Melanin binding is known to affect the distribution and elimination of ocular drugs. The purpose of this study was to evaluate if the extent of drug uptake to primary retinal pigment epithelial (RPE) cells could be estimated based on in vitro binding studies with isolated melanin and evaluate the suitability of single photon emission computed tomography/computed tomography (SPECT/CT) in studying pigment binding in vivo with pigmented and albino rats. Binding of five compounds, basic molecules timolol, chloroquine, and nadolol and acidic molecules methotrexate and 5(6)-carboxy-2',7'-dichlorofluorescein (CDCF), was studied using isolated melanin from porcine choroid-RPE at pH 5.0 and 7.4. The…
Correlation of cerebral blood flow and treatment effects of repetitive transcranial magnetic stimulation in depressed patients.
2002
The aims of this study were to: (1) assess the effects of repetitive transcranial magnetic stimulation (rTMS) on brain activity in depressed patients as measured by single photon emission tomography (SPECT); (2) evaluate the predictive value of brain SPECT on the antidepressant efficacy of rTMS. Patients (n=17) received 1600 rTMS stimuli at a rate of 10 Hz, 5 days per week for 2 weeks to the left dorsolateral prefrontal cortex. Whole brain SPECT data were acquired using Tc99m-Bicisate. Regional cerebral blood flow (rCBF) was correlated with the % change in the 28-item Hamilton Depression Rating Scale Score (Δ-HDRS) and a semiquantitative region of interest (ROI) analysis was conducted. Prio…
A weakly-interacting many-body system of Rydberg polaritons based on electromagnetically induced transparency
2020
We proposed utilizing a medium with a high optical depth (OD) and a Rydberg state of low principal quantum number, $n$, to create a weakly-interacting many-body system of Rydberg polaritons, based on the effect of electromagnetically induced transparency (EIT). We experimentally verified the mean field approach to weakly-interacting Rydberg polaritons, and observed the phase shift and attenuation induced by the dipole-dipole interaction (DDI). The DDI-induced phase shift or attenuation can be viewed as a consequence of the elastic or inelastic collisions among the Rydberg polaritons. Using a weakly-interacting system, we further observed that a larger DDI strength caused a width of the mome…
Multiexciton complex from extrinsic centers in AlGaAs epilayers on Ge and Si substrates
2013
The multiexciton properties of extrinsic centers from AlGaAs layers on Ge and Si substrates are addressed. The two photon cascade is found both in steady state and in time resolved experiments. Polarization analysis of the photoluminescence provides clearcut attribution to neutral biexciton complexes. Our findings demonstrate the prospect of exploiting extrinsic centers for generating entangled photon pairs on a Si based device. © 2013 AIP Publishing LLC.
The role of combined techniques of scintigraphy and SPECT/CT in the diagnosis of primary hyperparathyroidism
2019
Abstract Rationale: Primary hyperparathyroidism, usually as a result of a hyperfunctioning parathyroid gland, represents more than 90% cases of patients evaluated for hypercalcemia. Combined techniques of preoperative scintigraphy and SPECT/CT serve as a successful minimally-invasive parathyroidectomy. This recent imaging method provides four-dimensional functional images with advanced contrast resolution which greatly facilitates preoperative localization of parathyroid adenomas. Patient concerns: We presented the case of a male Caucasian patient, aged 67 years, who was investigated for hypercalcemia. Increased levels of parathormone, cervical ultrasonography without pathological changes, …
Single Photon Emission from Site-Controlled InAs Quantum Dots Grown on GaAs(001) Patterned Substrates
2009
5 páginas, 5 figuras.
A Search for Single Photon Events in Neutrino Interactions
2011
We present a search for neutrino induced events containing a single, exclusive photon using data from the NOMAD experiment at the CERN SPS where the average energy of the neutrino flux is ≃25 GeV. The search is motivated by an excess of electron-like events in the 200-475 MeV energy region as reported by the MiniBooNE experiment. In NOMAD, photons are identified via their conversion to e + e - in an active target embedded in a magnetic field. The background to the single photon signal is dominated by the asymmetric decay of neutral pions produced either in a coherent neutrino-nucleus interaction, or in a neutrino-nucleon neutral current deep inelastic scattering, or in an interaction occurr…
Mapping and quantification of biomolecules in tumor biopsies using bioluminescence
1996
Quantitative bioluminescence and single-photon imaging have been applied for mapping concentration distributions of metabolites, such as adenosine triphosphate (ATP), glucose and lactate, in biopsies of cervical cancers in patients. Biopsies were taken before a conventional radiation treatment, and a number of clinically relevant data, such as local tumor control, patient survival, metastatic spread and so forth, were documented. There was no correlation between staging or grading and any of the metabolic parameters measured. Local correlations between ATP, glucose and lactate on a pixel-to-pixel basis were generally positive, with respective Spearman's correlation coefficients less in pati…
Quantitative bioluminescence imaging--a method for the detection of metabolite distributions in frozen tissues
1994
A novel technique allows for measurement of metabolite distributions in tissue cryosections at a microscopic level using bioluminescence, single photon imaging, and computerized image analysis. Metabolites, such as ATP, glucose and lactate are registered in absolute concentration units, and the respective images can be correlated with each other and with histological structures by specific algorithms. One striking difference between malignant tumors and normal tissue is the pronounced heterogeneity of metabolite distributions in malignancies contrasted by rather homogeneous patterns obtained in many normal organs. The heterogeneous distribution of metabolites in solid tumors reflects the ch…